80CHAPTER 5: PLANNING THE 3COM MOBILITY SYSTEM

In AutoCAD, when you load the drawing file, you might see messages about the files not being found. To check for external references, you can select Insert > Xref Manager. If you look at the layers, externally referenced layers have a common prefix label with the $ delimiter between the label and the description (for example, SC03$a-WALL-FULL). If you can see the layer itself, the layer either will be blank or will be a single read-only object.

To include the information in externally referenced files, place the files in the same directory as the master file. In AutoCAD, you also can bind the information to the master file by selecting Insert > Xref Manager, selecting the file, then clicking Bind.

Adding information from referenced files can increase the file size. If the information you will need to convert into RF obstacles is in the referenced file but not the master file, try just importing the referenced file into 3WXM. For information on the location of referenced files in AutoCAD, see the AutoCAD documentation.

„Audit the drawing. An audit finds problems between objects in the file and fixes them automatically. To perform an audit in AutoCAD, select File > Drawing Utilities > Audit.

„Check for grouped objects, especially groups that span multiple layers or include the entire drawing. If a grouped object contains objects that you will to assign differing RF values to, or if some objects will not become RF obstacles, ungroup the objects and delete the unneeded objects. If all the RF objects in the grouped object will have the same RF value, you might want to leave the object grouped.

A grouped object can contain multiple layers, and can contain visible and invisible objects. (When you select an object that spans multiple layers, the object is not selected normally when you click on it.

Instead, a selection square appears, offset to the side of the object.) If you decide to delete a grouped object, ensure that the object does not contain objects to which you will need to assign RF values.

„Turn visible, unlock, and unfreeze all layers. Then delete unnecessary layers. (Locking a layer keeps the layer visible but also prevents changes to the layer. Freezing a layer locks the layer and makes it invisible.)

In many cases, the information in invisible or frozen layers is not related to objects that will be RF obstacles, and so is unnecessary in the floor plan. The information you need to keep is the structural information to which you will assign RF values in 3WXM.

Page 80
Image 80
3Com WX4400 3CRWX440095A WX1200, 3CRWXR10095A, 3CRWX120695A WXR100 manual Planning the 3COM Mobility System