How to Use the Console

Clearing of Absolute Encoder

Only applicable to the system which uses absolute encoder. You can clear the alarm and multi-turn data of the absolute encoder.

Operation at SELECTION display

Press five time after pressing , to setup auxiliary function mode, ￿

then with , make a display to

Operation at EXECUTION display

Press to call for ￿

EXECUTION DISPLAY of

Then keep pressing until the display of Console (LED) ￿

changes to

” increases by ￿

pressing (approx. 5sec) ￿ as the left fig. shows.

Clearing of absolute encoder starts

Clearing finishes

Clearing of absolute encoder ￿Error occurs￿

completes (When non-applicable encoder is)￿ connected

A incremental encoder or any unsupported encoder other than an absolute encoder may be connected. Reset the power supply and clear the error.

When you have cleared the absolute encoder, press to return to

SELECTION display

.

<Remarks>￿

 

 

Don't disconnect the console from the driver between

to

.￿

Should the connector is pulled out, insert it again and repeat the procedures from the beginning.￿

￿

<Notice>￿

If an error code No. 40 is shown on the console immediately after purchase, clear the absolute encoder through the console.