Conformity to EC Directives and UL Standards

EC Directives

The EC Directives apply to all such electronic products as those having specific functions and have been exported to EU and directly sold to general consumers. Those products are required to conform to the EU unified standards and to furnish the CE marking on the products.

However, our AC servos meet the relevant EC Directives for Low Voltage Equipment so that the machine or equipment comprising our AC servos can meet EC Directives.

EMC Directives

MINAS Servo System conforms to relevant standard under EMC Directives setting up certain model (condi- tion) with certain locating distance and wiring of the servo motor and the driver. And actual working condition often differs from this model condition especially in wiring and grounding. Therefore, in order for the machine to conform to the EMC Directives, especially for noise emission and noise terminal voltage, it is necessary to examine the machine incorporating our servos.

Conformed Standards

Subject

 

Conformed Standard

 

 

 

Motor￿

IEC60034-1 IEC60034-5 UL1004 CSA22.2 No.100 ￿

 

Conforms to Low-￿

 

 

￿

EN50178 UL508C￿

 

Voltage Directives￿

 

 

￿

EN55011￿

Radio Disturbance Characteristics of Industrial, Scientific

￿

￿

 

 

￿

 

 

￿

 

and Medical (ISM) Radio-Frequency Equipment￿

 

￿

 

Motor/￿

EN61000-6-2￿

Immunity for Industrial Environments￿

 

￿

 

 

 

 

 

 

Standards ￿

 

Motor ￿

IEC61000-4-2￿

Electrostatic Discharge Immunity Test￿

 

 

 

referenced by ￿

 

and ￿

IEC61000-4-3￿

Radio Frequency Electromagnetic Field Immunity Test￿

 

 

 

 

 

driver

IEC61000-4-4￿

Electric High-Speed Transition Phenomenon/Burst Immunity Test￿ EMC Directives

 

 

 

IEC61000-4-5￿

Lightening Surge Immunity Test￿

 

 

 

 

 

IEC61000-4-6￿

High Frequency Conduction Immunity Test ￿

 

 

 

 

 

IEC61000-4-11￿ Instantaneous Outage Immunity Test

 

 

 

IEC

: International Electrotechnical Commission

 

 

 

EN

: Europaischen Normen

 

 

 

EMC : Electromagnetic Compatibility

 

 

 

UL

: Underwriters Laboratories

 

 

 

CSA : Canadian Standards Association

 

 

 

<Precautions in using options>

Use options correctly after reading operation manuals of the options to better understand the precautions. Take care not to apply excessive stress to each optional part.

Composition of Peripheral Equipments

Installation Environment

Use the servo driver in the envi- ronment of Pollution Degree 1 or 2 prescribed in IEC-60664-1 (e.g. Install the driver in control panel with IP54 protection structure.)

Control box

 

 

Controller

 

 

 

 

 

Insulated power supply ￿

 

 

 

 

 

for interface

 

CN X5

 

 

 

 

 

 

 

 

Noise filters for ￿

Driver

Noise filters ￿

Power ￿

 

 

 

 

signal lines

CN X1

for ￿

supply

 

 

signal lines

Circuit ￿

Ground-fault ￿

 

L1

 

Noise filter

 

 

breaker

breaker (RCD)

L2

CN X2

Motor

 

 

 

L3

U

 

 

 

 

L1C

V

M

 

 

 

W

 

 

Surge ￿

 

L2C

 

RE

 

 

 

 

 

 

 

 

 

 

absorber

 

 

 

CN X6

 

 

 

 

 

Protective earth (PE)