Panasonic A4P Series instruction manual Parameters for Full-Closed Control, Setup value Content

Models: A4P Series

1 232
Download 232 pages 51.05 Kb
Page 72
Image 72

Parameter Setup

 

 

 

 

Standard default : < >

Servo￿

Title

Setup￿

Unit

Function/Content

 

PrNo.

 

range

 

 

 

73

Setup of ￿

0 to 20000

￿ r/min

• You can set up the over-speed level. The over-speed level becomes 1.2

 

 

over-speed level

<0>

 

times of the motor max. speed by setting up this to 0.￿

 

 

 

 

 

• Use this with 0 setup in normal operation. Set up other value only when

 

 

 

 

 

you need to lower the over-speed level. ￿

 

 

 

 

 

• The setup value of this parameter is limited by 1.2 times of the motor

 

 

 

 

 

max. speed.￿

 

 

 

 

 

<Caution> ￿

 

 

 

 

 

The detection error against the setup value is ±3 [r/min] in case of the 7-wire

 

 

 

 

 

absolute encoder, and ±36 [r/min] in case of the 5-wire incremental encoder.

 

 

 

 

 

 

 

Parameters for Full-Closed Control

 

 

 

 

 

 

 

 

 

 

Standard default : < >

Servo￿

Title

Setup￿

 

Unit

 

 

 

 

Function/Content

 

 

 

 

PrNo.

 

range

 

 

 

 

 

 

 

 

 

 

 

78￿

Numerator of ￿

0 to 32767

￿

–￿

You can setup the ratio between the encoder resolution and the external

 

*￿

external scale ￿

<10000>

￿

￿

scale resolution at full-closed control.

 

 

 

 

(F)

ratio￿

￿

 

￿

 

 

Encoder resolution per one motor revolution￿

 

SV.Pr78 X 2 SV.Pr79￿

 

 

 

 

 

=

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

￿

￿

 

￿

 

External scale resolution per one motor revolution

SV.Pr7A

 

 

 

 

 

 

 

￿

￿

 

￿

• SV.Pr78= 0

￿

 

 

 

 

79￿

Multiplier of ￿

0 to 17￿

 

–￿

 

Numerator equals to encoder resolution, and you can setup ￿

 

*￿

numerator of ￿

<0>￿

 

￿

 

the external scale resolution per one motor revolution with SV.Pr7A.￿

 

(F)

external scale ￿

￿

 

￿

• SV.Pr78 0,￿

 

 

 

 

 

 

 

 

 

 

 

 

 

Setup the ratio between the external scale resolution and the encoder

 

 

ratio￿

￿

 

￿

 

 

 

 

￿resolution per one motor revolution according to the above formula.￿

 

 

￿

￿

 

￿

 

 

 

 

 

 

<Caution>￿

 

 

 

 

 

7A￿

Denominator of ￿

1 to 32767

￿

–￿

 

 

 

 

 

• Upper limit

of numerator value after calculation

is 131072. Setup

 

*￿

external scale ￿

<10000>

 

 

 

 

 

 

exceeding this value will be invalidated, and 131702 will be the actual

 

(F)

ratio

 

 

 

 

 

 

 

 

 

 

numerator.￿

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• The actual calculation of numerator is “numerator of external scale

 

 

 

 

 

 

 

division (SV.Pr78) x 2 to the nth power (a set value of SV.Pr79)”.

 

 

 

 

 

 

 

 

 

 

 

 

7B￿

Hybrid deviation

1 to 10000

￿

16 x

• You can setup the permissible gap (hybrid deviation) between the

 

*￿

error level

<100>

external

 

present motor position and the present external scale position.

 

(F)

 

 

 

scale

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pulse

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7C￿

External scale ￿

0 to 1￿

 

–￿

You can set up the logic of the absolute data of the external scale.

 

*￿

direction￿

<0>

 

 

 

 

 

 

 

 

 

 

 

 

Setup value

￿

Content￿

 

 

 

 

(F)

 

 

 

 

 

 

 

 

 

 

 

 

 

￿

 

 

 

 

 

￿

 

Serial data will increase when the detection head travels

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0￿

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to the right viewed from the mounting side. (+ count)￿

 

 

 

 

 

 

 

 

 

￿

 

 

 

 

 

 

 

 

 

 

 

Serial data will decrease when the detection head travels

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

to the right viewed from the mounting side. (– count)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<Caution>￿

 

 

 

 

 

 

 

 

 

 

Unlike 16.Pr50 (setup of operating direction), this parameter depends on

 

 

 

 

 

 

the mounting direction of external scale. Please note that the full-closed

 

 

 

 

 

 

control cannot be executed appropriately in a reverse setting.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<Notes>

Anything marked with “(F)” on the servo parameter number (Servo PrNo.) can be used only for the “Full- Closed Control”.

For servo parameters which No. have a suffix of "*", changed contents will be validated when you turn on the control power.

72

Page 72
Image 72
Panasonic A4P Series instruction manual Parameters for Full-Closed Control, Setup value Content