Panasonic A4P Series instruction manual Oil/Water Protection

Models: A4P Series

1 232
Download 232 pages 51.05 Kb
Page 24
Image 24

How to Install

Motor

Installation Place

Since the conditions of location affect a lot to the motor life, select a place which meets the conditions below.

1)Indoors, where the products are not subjected to rain or direct sun beam. The products are not water- proof.

2)Where the products are not subjected to corrosive atmospheres such as hydrogen sulfide, sulfurous acid, chlorine, ammonia, chloric gas, sulfuric gas, acid, alkaline and salt and so on, and are free from splash of inflammable gas, grinding oil, oil mist, iron powder or chips and etc.

3)Where the motor is free from grinding oil, oil mist, iron powder or chips.

4)Well-ventilated and humid and dust-free place, far apart from the heat source such as a furnace.

5)Easy-to-access place for inspection and cleaning.

6)Vibration-free place.

7)Avoid enclosed place. Motor may gets hot in those enclosure and shorten the motor life.

Environmental Conditions

 

Item￿

 

Condition￿

 

Ambient temperature￿

0˚C to 40˚C (free from freezing) *1￿

 

Ambient humidity￿

Less than 85% RH (free from condensation)￿

 

Storage temperature￿

–20˚C to 80˚C (free from freezing) *2￿

 

Storage humidity￿

Less than 85% RH (free from condensation)￿

￿

Vibration￿

 

Motor only￿

Lower than 49m/s2 (5G) at running, 24.5m/s2 (2.5G) at stall￿

￿

Impact￿

 

Motor only￿

Lower than 98m/s2 (10G)￿

￿

￿

 

 

IP65 (except rotating portion of output shaft and lead wire end)￿

￿

 

 

 

• These motors conform to the test conditions specified in EN

￿ Enclosure rating￿

 

Motor only

standards (EN60529, EN60034-5). Do not use these motors in

 

 

 

 

application where water proof performance is required such as

 

 

 

 

continuous wash-down operation.

*1 Ambient temperature to be measured at 5cm away from the motor. *2 Permissible temperature for short duration such as transportation.

How to Install

You can mount the motor either horizontally or vertically as long as you observe the followings.

1)Horizontal mounting

Mount the motor with cable outlet facing downward for water/oil countermeasure.

2)Vertical mounting

Use the motor with oil seal (non-standard) when mounting the motor with gear reducer to prevent the reducer oil/grease from entering to the motor.

3)For mounting dimensions, refer to P.195 to 209 "Dimensions".

Oil/Water Protection

1)Don't submerge the motor cable to water or oil.

2)Install the motor with the cable outlet facing downward.

3)Avoid a place where the motor is subjected to oil or water.

4)Use the motor with an oil seal when used with the gear reducer, so that the oil may not enter to the motor through shaft.

Cable Motor

Oil, water

24

Page 24
Image 24
Panasonic A4P Series instruction manual Oil/Water Protection