Image 92

How to Use the Console

Step Parameter

Step parameter can be set.

* An example to set in ST.Pr1 is shown below.

 

 

Step data￿

 

 

 

 

Step data￿

Press

.

(low order)

 

Press

.

 

(high order)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

.....ST.Pr01

A selected parameter ￿

 

 

is shown.

.....ST.Pr02

.....ST.Pr60

.....ST.Pr01

 

 

* The data is shown on the ￿

Press

.

two screens because of a ￿

 

 

large number of displayed ￿

 

 

digits.

 

.....Speed number selection

Press

.

 

 

.....Acceleration number selection

Press

.

 

 

.....Deceleration number selection

Press

.

 

 

.....Operation mode selection

Press

.

 

 

.....Block selection

Press

.

 

<Notice>￿

Select an input digit (a dot blinks) by the [SHIFT] key and a parameter by the [UP]/[DOWN] key.￿ The step data is shown on the two screens because of a large number of displayed digits.￿

If the parameter is a negative value, a dot lights. ￿

When you press the [SET] key, the parameter is modified.￿

￿

*When you press during parameter setting, any parameter in process is not changed and “No.” display is shown again.￿

*When you have set the parameters, write the parameters into EEPROM. If you turn the power supply off before writing the parameters into EEPROM, those parameters are cleared.