How to Use the Console

Display of Regenerative Load Factor

Shows regenerative resistance load factor in percentage assuming that an operation level of regenerative protection is 100%.￿

This is valid when SV.Pr6C is 0 or 1.

Display of Over-load Factor

Displays the ratio (%) against the rated load. ￿￿

Refer to P.170, "Overload Protection Time Characteristics" of When in Trouble.

Display of Inertia Ratio

Displays the inertia ratio (%) .￿￿

Value of SV.Pr20 (Inertia ratio) will be displayed as it is.

Display of Feedback Pulse Sum, Command Pulse Sum

(lowestorder ￿)

Press .

(highestorder ￿)

Total sum of pulses after control power-ON. ￿

The display range is from –2147483647 to 2147483647.￿ An overflow occurs if the result is outside the display range.￿

Sum of pulses shown can be reset to “0” by pressing ￿ for approximately 5 seconds or more.

Display of External Scale Deviation, External Scale Feedback Pulse Sum

Press

.

 

* Not available to the models that do not

 

support external scale.

 

 

(lowestorder ￿)

Press

.

 

 

 

 

Press

.

 

(highestorder ￿)

Automatic Motor Recognizing Function

Automatic recognition is valid. (This is always shown.)

Switching of the Driver to be Communicated

RS232 communication

.....“1” is always shown.

86

Page 86
Image 86
Panasonic A4P Series Display of Regenerative Load Factor, Display of Over-load Factor, Display of Inertia Ratio