13 SIMATIC NCM PC Project Engineering Tool

13.9.1Online Mode

The online mode allows you to download the configuration data directly to a PC station attached to the network (MPI, PROFIBUS or Ethernet), or to load the data on the local PC station if you are using this as the configuration station.

SOnline mode - networked (engineering station networked with runtime PC)

Runtime PC

Engineering station

Download

Use this option when the following requirements are met:

SThe PC station (runtime PC) is not the configuration station.

SThe PC station (runtime PC) is linked to the configuration station via a network. The PC station is accessible as a communications node, for example after setting the parameters in the initial configuration.

SA connection exists that can, for example, be checked using the “Accessible Nodes” function.

Follow the steps below:

 

Procedure for “Downloading Project Engineering Data to the PC

Tool

 

Station” -

 

 

Online - Networked

 

 

 

 

1.

Check the following on the runtime PC:

Station

 

S The mode is set to online.

Configuration

 

Editor

 

S The runtime PC is not disabled.

 

 

 

 

 

2.

Select the station you want to download to.

NCM PC / STEP 7

 

 

 

3.

Download the configuration data with PLC -> Download

NCM PC / STEP 7

 

If you are using PG operation: Make sure that you set the correct

 

 

interface using the Set PG/PC Interface tool (access point “S7ONLINE“)

.

 

 

 

Commissioning PC Stations - Manual and Quick Start

185

Release 5/2005

C79000-G8976-C156-07

Page 185
Image 185
Siemens C79000-G8976-C156-07 quick start Online Mode, Follow the steps below