A Notes for Users of Older Versions

SOFTNET-DP up to version 5.3 for Windows 2000 Pro, Windows NT 4.0 or Windows 98

Situation:

Windows 98 is no longer supported.

A DP project engineering configuration created with the COM PROFIBUS program cannot be used.

It will be possible to configure SEND/RECEIVE communication on the basis of the FDL interface over OPC with SIMATIC NCM PC or STEP 7 in the future!

What to do:

Under Windows 98, use the SIMATIC NET CD 05/2000.

A DP project engineering configuration created with the COM PROFIBUS program must be recreated with SIMATIC NCM PC V5.1 Service Pack 2 or higher or STEP 7 Version 5.1 Service Pack 2 or higher.

If the project engineering configuration was already created with STEP 7, this STEP 7 project can continue to be used. You only need to download the project engineering data to the CP/PC station from STEP 7 Version 5.1 Service Pack 2 or higher.

SOFTNET-DP slave up to version 1.2 for Windows 2000 Pro, Windows NT 4.0 or Windows 98

Situation:

Windows 98 is no longer supported.

What to do:

Under Windows 98, use the SIMATIC NET CD 05/2000.

Commissioning PC Stations - Manual and Quick Start

285

Release 5/2005

C79000-G8976-C156-07