18 DCOM Settings with the dcomcnfg System Program

18.6.4“Security” Tab

Introduction

You specify the access permissions for the OPC server in the “Security” tab.

For the three aspects relevant to COM objects, you can either use the default permissions or user-defined permissions for the selected COM object.

Notice

If you select the default settings in the “Security” tab, you must make sure that the necessary rights are available for the account entered in the “Identity” tab.

If you do not want a particular user to have all COM objects of the system available, you must configure user-defined permissions. To operate the OPC server, only the access permission and the launch permission need to be configured.

Commissioning PC Stations - Manual and Quick Start

267

Release 5/2005

C79000-G8976-C156-07

Page 267
Image 267