Siemens C79000-G8976-C156-07 quick start InitiateTimeout Parameter

Models: C79000-G8976-C156-07

1 300
Download 300 pages 4.08 Kb
Page 290
Image 290

B Description of the PROFINET Configuration File

The InitiateTimeout Parameter

This parameter is specified in section [<connectionname>].

The connection name contains the IP address from the iMap project engineering (network view) and the PROFInet device name configured in iMap.

Parameter

Meaning

 

 

Syntax

[192.11.2.34S7-300 Station (1)]

 

InitiateTimeout = 15000

 

 

Purpose

If a connection establishment job cannot be

 

processed within the InitiateTimeout time, the

 

connection is reset and the job is started again.

 

Particularly when establishing connections using

 

DCOM from Microsoft, wait times of several

 

minutes can occur if the partner does not exist or if

 

the connection has broken down. During this time,

 

further actions on the connection are blocked

 

because the access is synchronous. This wait time

 

can be reduced with this parameter.

 

 

Default

10000

 

 

Possible Values

milliseconds

 

 

290

Commissioning PC Stations - Manual and Quick Start

Release 5/2005

C79000- G8976- C156 - 07

Page 290
Image 290
Siemens C79000-G8976-C156-07 quick start InitiateTimeout Parameter