A Notes for Users of Older Versions
A.4 Industrial Ethernet - Effects on Older Product Versions (SIMATIC NET CD 05/2000 and earlier)
Introduction
This section describes what changes are necessary in Industrial Ethernet systems if you are already using a SIMATIC NET CD 05/2000 product or a previous version.
Situation:
These products are not supported by the SIMATIC NET CD 07/2001.
Simultaneous installation of these products with products of the new CD 07/2001 is not permitted and is prevented.
What to do:
Keep using the products of the SIMATIC NET 5/2000 CD if you want to use a CP 1413 in your computer or replace it with a CP 1613.
Situation:
PG operation possible as before.
What to do:
No action necessary
Situation:
S7 project engineering created with the COML S7 program cannot be used.
What to do:
A project engineering configuration created with the COML S7 program must be recreated with SIMATIC NCM PC V5.1 Service Pack 2 or higher or STEP 7 Version 5.1 Service Pack 2 or higher.
If the project engineering configuration was already created with STEP 7 (XDB), this STEP 7 project can continue to be used. You only need to download the project engineering data to the CP/PC station from STEP 7 Version 5.1 Service Pack 2 or higher.
Commissioning PC Stations - Manual and Quick Start | 281 |
Release 5/2005 |