A.4 Industrial Ethernet - Effects on Older Product Versions (SIMATIC NET CD 05/2000 and earlier)

Introduction

This section describes what changes are necessary in Industrial Ethernet systems if you are already using a SIMATIC NET CD 05/2000 product or a previous version.

PG-1413, S7-1413, TF-1413 up to version 5.2 with Service Pack 2 for Windows NT 4.0 or Windows 98

Situation:

These products are not supported by the SIMATIC NET CD 07/2001.

Simultaneous installation of these products with products of the new CD 07/2001 is not permitted and is prevented.

What to do:

Keep using the products of the SIMATIC NET 5/2000 CD if you want to use a CP 1413 in your computer or replace it with a CP 1613.

PG-1613 up to version 2.1 for Windows 2000 Pro or Windows NT 4.0

Situation:

PG operation possible as before.

What to do:

No action necessary

S7-1613 up to version 2.1 for Windows 2000 Pro or Windows NT 4.0

Situation:

S7 project engineering created with the COML S7 program cannot be used.

What to do:

A project engineering configuration created with the COML S7 program must be recreated with SIMATIC NCM PC V5.1 Service Pack 2 or higher or STEP 7 Version 5.1 Service Pack 2 or higher.

If the project engineering configuration was already created with STEP 7 (XDB), this STEP 7 project can continue to be used. You only need to download the project engineering data to the CP/PC station from STEP 7 Version 5.1 Service Pack 2 or higher.