6 Using the CP 1616 as a PROFINET IO Controller/Device

Using the CP 1616 as a PROFINET IO Device

1.

2.

3.

4.

5.

To use the CP 1616 as PROFINET IO device, select (or create) a project containing a PROFINET IO controller, a PROFINET IO system and possibly also devices (for example ET 200S).

Follow the steps outlined below

Open the project in the SIMATIC Manager.

Open the configuration (HW Config) of the station containing the PROFINET IO controller.

In the hardware catalog (PROFINET IO " I/O " SIMATIC PC CP), select the CP 1616 and position it in the network (PROFINET IO system).

This configures the CP 1616 is as a device in the network.

Enter the device name in the “Device name” input box.

Make sure that the device name is identical to the device name of the CP 1616 in the PC station.

Disable the “Assign IP address via IO Controller” option.

Based on the device name, the IP address of the CP 1616 is then assigned during compilation.

Note

If the CP1616 was configured previously as a controller, you must first run a complete memory reset before the device name can be changed.

Following every memory reset, the CP must be restarted (by STEP 7) otherwise operation as a device is not possible!

74

Commissioning PC Stations - Manual and Quick Start