1 Welcome to Advanced PC Configuration

1.4.3Commissioning for Configured Mode - Overview

When commissioning in the configured mode, three situations can be distinguished. The situation depends on whether or not project engineering data is already available in the form of an XDB file or whether commissioning is independent of project engineering (no XDB file).

Initial configuration means the step in commissioning at which the module is switched to “configured mode” and obtains addresses and network parameters .

SCase aInitial Configuration by Remote Configuration with STEP 7 / NCM PC

With this method, it is assumed that the PC station and its components and applications is first created in project engineering in STEP 7 / NCM PC. The target PC station that can be reached over an Ethernet adapter (online) is then configured remotely over STEP 7 / NCM PC (applies to Ethernet and PROFIBUS).

The advantage of this is that the project engineering data and the PC configuration are consistent and the total effort is minimal.

 

Step

How does it work?

 

Tool

 

 

 

 

1.

Installing SIMATIC

Install the SIMATIC NET software

SIMATIC NET CD / Windows

 

NET Software on the

based on the installation instructions

 

 

 

Engineering PC/PG

 

 

 

 

and on the PC Station

 

 

 

 

 

 

 

2.

Installing the

Install the communication module in the

Refer to the documentation on the

 

hardware (PC

PC station

CP

 

 

modules)

 

 

 

 

 

 

 

3.

Project Engineering

Steps in project engineering of the PC

NCM PC / STEP 7

 

on the PC Station

station:

 

 

 

 

S Create the PC station in NCM PC

S

SIMATIC Manager

 

 

S Enter modules and applications

S

HW Config

 

 

S Create connections in NetPro

S

NetPro

 

 

S Use symbols (in the project

S

HW Config

 

 

engineering of the OPC server)

 

 

 

 

 

 

4.

Initial configuration

Remote configuration with the menu

NCM PC / STEP7

 

 

command “PLC Configure”

 

 

 

 

"

 

 

 

 

 

 

5.

Downloading the

Download the project engineering data

NCM PC / STEP7

 

Project Engineering

with the menu command ”PLC "

 

 

 

Data to the PC Station

Download”

 

 

 

 

 

 

 

Result:

PC station is ready for productive communication

6.Testing the configuration

Configuration Console

Configuration Console

22

Commissioning PC Stations - Manual and Quick Start

Release 5/2005

C79000-G8976-C156-07

Page 22
Image 22