5 Project Engineering for the OPC Server

Table 5-1

Parameter

Possible Settings / Significance

 

Can be set for a specific protocol

 

/ Function

 

 

 

 

 

 

 

 

 

 

 

DP

FDL

FMS

S7

ISO/TCP

DP class 2

PROFInet

PROFInetIO

SNMP

 

 

 

 

 

 

 

 

 

 

 

 

 

Scan cycle

Here, you make the settings to control

x

x

x

x

x

x

x

x

x

time

updating by the OPC Server.

 

 

 

 

 

 

 

 

 

 

The scan cycle time decides how often

 

 

 

 

 

 

 

 

 

 

the OPC server updates the values the

 

 

 

 

 

 

 

 

 

 

OPC items.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Access

You can specify the access rights to

x

x

x

x

x

x

x

x

x

protection

individual variables or variable groups for

 

 

 

 

 

 

 

 

 

 

each specific protocol. You can, for

 

 

 

 

 

 

 

 

 

 

example, prevent variables calculated

 

 

 

 

 

 

 

 

 

 

internally by the controller from being

 

 

 

 

 

 

 

 

 

 

overwritten.

 

 

 

 

 

 

 

 

 

 

As default, no access protection is

 

 

 

 

 

 

 

 

 

 

activated.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VFD

VFD (Virtual Field Device) is the neutral

 

 

x

 

 

 

 

 

 

 

description of a device used in FMS.

 

 

 

 

 

 

 

 

 

 

Communication connections (FMS

 

 

 

 

 

 

 

 

 

 

connections) are then configured for the

 

 

 

 

 

 

 

 

 

 

VFDs in project engineering.

 

 

 

 

 

 

 

 

 

 

Here, you inform the OPC server of the

 

 

 

 

 

 

 

 

 

 

required VFDs. During project

 

 

 

 

 

 

 

 

 

 

engineering, you then assign the VFD to

 

 

 

 

 

 

 

 

 

 

the FMS connection. When accessing

 

 

 

 

 

 

 

 

 

 

variables in the PC application, you also

 

 

 

 

 

 

 

 

 

 

reference the VFD.

 

 

 

 

 

 

 

 

 

 

Extra function: creating the object

 

 

 

 

 

 

 

 

 

 

dictionary

 

 

 

 

 

 

 

 

 

 

Here, you can also create the object

 

 

 

 

 

 

 

 

 

 

dictionary (OD) belonging to a VFD. The

 

 

 

 

 

 

 

 

 

 

FMS variables (name and structure) are

 

 

 

 

 

 

 

 

 

 

defined in the object dictionary.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connection

Here, you can make the settings required

 

 

 

x

 

 

 

 

 

parameters

for communication for services that do

 

 

 

 

 

 

 

 

 

 

not require specific connections to be

 

 

 

 

 

 

 

 

 

 

configured in project engineering.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Segmenta-

Special settings for providing the data

 

 

 

 

x

 

 

 

 

tion

buffers independent of specific

 

 

 

 

 

 

 

 

 

 

connections.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Use

 

 

 

 

x

 

 

 

 

 

symbols

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Please note that the parameters are described in detail in the online help for each individual dialog in NCM PC.

Commissioning PC Stations - Manual and Quick Start

59

Release 5/2005

C79000-G8976-C156-07

Page 59