10Example — SNMP Communication with OPC

Activity

4.

The settings are then visible in the window of the plant configuration.

With “Import Nodes”, all devices that have an IP address and exist in the current project are included automatically in the list of the plant configuration. If the device supports Web based management, this can be started with the “Web based Management ...” button (make sure your browser settings are suitable).

5.Click on “OK” to close the plant configuration window.

6.Click on “OK” again in the dialog box for the properties of the OPC Server to complete configuration of the SNMP OPC Server.

7.Select the NCM PC menu and then the menu item “Station " Save and Compile”.

8.Select the NCM PC menu and then the menu item “PLC " Download to Module”. The configuration data are downloaded to the OPC Server.

9.The OPC Server starts with the new configuration data. Confirm the next window with “OK”.

134

Commissioning PC Stations - Manual and Quick Start

Release 5/2005

C79000-G8976-C156-07

Page 134
Image 134
Siemens C79000-G8976-C156-07 quick start 134