13 SIMATIC NCM PC Project Engineering Tool
Note
To make it possible to identify the PC station, the station name in the configuration must match the locally configured station name. If this is not the case, it is not possible to adopt the configuration on the PC station!
Set the station name, if necessary, in the Station Configuration Editor.
Follow the steps below to create and import an XDB file:
Procedure for
“Downloading Project Engineering Data to the PC Station” - Offline
Tool
1.
2.
Select the station you want to load to in the STEP 7 project. | NCM PC / STEP 7 |
Open the object properties of the station with the “Station Properties” | NCM PC / STEP 7 |
menu command and select the “Configuration” tab. |
|
|
|
3. | Here, you can check and, if necessary, change the setting under | NCM PC / STEP 7 |
| “Storage Location of the Configuration File”. |
|
|
|
|
4. | Save and compile your project; you will then find the required XDB file in | NCM PC / STEP 7 |
| the folder you have selected. |
|
| Note: |
|
| The station name must be identical in the defined configuration and on |
|
| the local PC station (entry in the Station Configuration Editor). |
|
|
|
|
5. | Copy the XDB file onto a data medium that the destination station can | NCM PC / STEP 7 |
| access. |
|
|
|
|
6. | Import the XDB file into your destination station using the Station | Station |
| Configuration Editor. | Configuration |
|
| Editor |
|
|
|
188 | Commissioning PC Stations - Manual and Quick Start |
Release 5/2005 |