Teledyne 9110T Option Description/Notes Reference Number, Ambient Zero and Ambient Span Valves

Models: 9110T

1 378
Download 378 pages 16.38 Kb
Page 25
Image 25

 

Model 9110TH NOx Analyzer

Introduction

 

 

 

 

 

 

Option

Option

Description/Notes

Reference

Number

 

 

 

 

 

Carrying Strap/Handle

Side-mounted strap for hand-carrying analyzer

 

 

 

 

 

Extends from “flat” position to accommodate hand for carrying.

 

 

 

 

29

Recesses to 9mm (3/8”) dimension for storage.

N/A

 

 

Can be used with rack mount brackets, Option 21.

 

 

 

 

 

 

 

 

Cannot be used with rack mount slides.

 

 

 

 

 

CAUTION – GENERAL SAFETY HAZARD

 

 

THE 9110T ANALYZER WEIGHS ABOUT 18 KG (40 POUNDS).

TO AVOID PERSONAL INJURY WE RECOMMEND THAT TWO PERSONS LIFT AND CARRY THE ANALYZER. DISCONNECT ALL CABLES AND TUBING FROM THE ANALYZER BEFORE MOVING IT.

 

Analog Input and USB port

 

 

Used for connecting external voltage signals from other instrumentation (such as

 

 

 

 

meteorological instruments).

 

 

 

 

 

 

 

 

 

 

 

64B

 

Also can be used for logging these signals in the analyzer’s internal

Sections 3.3.1.2,

 

 

 

 

DAS

 

and 7

 

 

 

 

 

 

 

 

 

Current Loop Analog

 

Adds isolated, voltage-to-current conversion circuitry to the analyzer’s analog

 

 

Outputs

 

outputs.

 

 

 

 

 

 

 

 

Can be configured for any output range between 0 and 20 mA.

Sections 3.3.1.4

 

41

 

 

May be ordered separately for any of the analog outputs.

 

 

 

and 5.9.3.7

 

 

 

 

 

 

Can be installed at the factory or retrofitted in the field.

 

 

 

 

 

 

 

 

 

Parts Kits

 

Spare parts and expendables

 

 

 

 

 

 

 

Expendables Kit includes a recommended set of expendables for

 

 

 

 

42A

 

one year of operation of this instrument including replacement

Appendix B

 

 

 

 

 

 

sample particulate filters.

 

 

43

 

 

Expendables Kit with IZS includes the items needed to refurbish

Appendix B

 

 

 

the zero air scrubber.

 

 

 

 

 

 

 

 

45

 

 

Spare Parts Kit includes spares parts for one unit.

Appendix B

 

 

Calibration Valves

 

 

Used to control the flow of calibration gases generated from external sources,

 

 

 

 

rather than manually switching the rear panel pneumatic connections.

 

 

 

 

 

 

 

 

 

50A

 

AMBIENT ZERO AND AMBIENT SPAN VALVES

Section 3.3.2.3

 

 

 

 

Zero Air and Span Gas input supplied at ambient pressure.

 

 

 

 

 

 

Gases controlled by 2 internal valves; SAMPLE/CAL & ZERO/SPAN.

 

 

 

 

 

 

 

AMBIENT ZERO AND PRESSURIZED SPAN VALVES

 

 

 

 

 

 

 

Span Gas input from external, pressurized source;

 

 

 

 

 

 

 

Span Gas flow rate maintained at 1 ATM by critical flow orifice & vented

 

 

 

 

50B

 

through Vent port.

Section 3.3.2.4

 

 

 

 

Shutoff valve stops flow of Span Gas when in sample mode to preserve

 

 

 

 

 

 

 

 

 

 

 

 

 

pressurized gas source.

 

 

 

 

 

 

 

Zero Air created via 2-stage scrubber & dry filter unit (DFU).

 

 

 

 

 

 

 

Gases controlled by 2 internal valves; SAMPLE/CAL & ZERO/SPAN.

 

 

 

 

 

 

 

ZERO SCRUBBER AND INTERNAL SPAN SOURCE (IZS)

Sections 3.3.2.5

 

 

 

50G

 

Span Gas generated from internal NO2 permeation tube

 

 

 

 

Zero Air created by 2-stage scrubber & DFU.

and 3.3.2.6

 

 

 

 

 

 

 

 

 

 

 

 

Gases controlled by 2 internal valves: Sample/Cal & Zero/Span.

 

 

 

NO2 Permeation Tubes

 

 

Replacement tubes; identical size/shape; different permeation rates.

 

 

 

 

 

 

Permeation Rate

Approximate NO2 Concentration @ 50°C

 

 

 

 

 

 

(± 25%)

 

 

 

 

 

52B

 

421 ng/min

300ppb – 500 ppb ± 25%

N/A

 

 

 

52G

 

842 ng/min

0600 – 1000 ppb ± 25%

N/A

 

 

 

Each tube comes with a calibration certificate, traceable to a NIST standard,

Section 3.3.2.5

 

 

 

specifying its actual effusion rate of that tube to within ± 5% @ 0.56 liters per

 

 

 

 

 

Teledyne Analytical Instruments

25

Page 25
Image 25
Teledyne instruction manual Option Description/Notes Reference Number, 9110T Analyzer Weighs about 18 KG 40 Pounds