Model 9110TH NOx Analyzer

Specific Configuration

INFORMATION ABOUT THE SPECIFIC CONFIGURATION OF YOUR MODEL 9110T NOX ANALYZER

Note: All instruments must include the standard hardcopy manual.

SELECTED VERSIONS OF THE MODEL 9110T

Model 9110T— Standard Touch Screen Version

This Model 9110E NOx Analyzer is a touch screen version designed for analyzing the NOx concentration in a background gas specified by the customer. It has a minimum settable range of 0-50 ppb and a maximum settable range of 0-10 ppm. The standard version is designed for ambient pressure applications. The analyzer may have one or two analysis ranges with or without auto-ranging as listed below. It includes an internal Moly converter and an external pump. Alarm relays are optional and if included, that option will be checked below.

Model 9110TH — High Range Touch Screen Version

The Model 9110EH NOx Analyzer is a touch screen version designed for analyzing higher NOx concentration (from 0-5 ppm to 0-5000 ppm) than the standard model. It includes an internal Hicon converter and an external pump. Alarm relays are optional and if included, that option will be checked below. There is no internal zero/span gas/oven option available for this model. The analyzer may have one or two analysis ranges with or without autoranging as listed below.

This version is available with internal or external Hicon or Moly converters.

Model 9110TM — Mid-Range Touch Screen Version

The Model 9110EA NOx Analyzer is a touch screen version designed for analyzing a mid-range NOx concentration. It has a minimum settable range of 0-1 ppm and a maximum settable range of 0-200 ppm. t includes an internal Moly converter and an external pump. Alarm relays are optional and if included, that option will be checked below. There is no internal zero/span gas/oven option available for this model. The analyzer may have one or two analysis ranges with or without autoranging as listed below.

This model is similar to the EH version but does not have a sample bypass line. An optional paramagnetic oxygen sensor is available for oxygen analysis in this version.

Converter Options

The 9110 is equipped with an internal Hicon thermal converter as standard equipment. Other converters are available for the EH version as follows:

Internal Hicon (standard)

External Hicon (2nd set of rack mounts req’d)

Internal Moly

External Moly (2nd set of rack mounts req’d)

Teledyne Analytical Instruments

iii

Page 3
Image 3
Teledyne instruction manual Model 9110T- Standard Touch Screen Version, Model 9110TH NOx Analyzer Specific Configuration