Teledyne 9110T Password Security, Primary Setup Menu, Secondary Setup Menu Setup MORE

Models: 9110T

1 378
Download 378 pages 16.38 Kb
Page 93
Image 93

Model 9110TH NOx Analyzer

Overview of Operating Modes

4.3.1. PASSWORD SECURITY

SETUP Mode can be protected by password security through the SETUP>PASS menu (Section 5.5) to prevent unauthorized or inadvertent configuration adjustments.

4.3.2. PRIMARY SETUP MENU

The areas accessed and configured under the primary SETUP Mode menu are shown in Table 4-4.

Table 4-4: Primary Setup Mode Features and Functions

 

CONTROL

 

MANUAL

MODE OR FEATURE

BUTTON

DESCRIPTION

SECTION

 

LABEL

 

 

Analyzer Configuration

CFG

Lists button hardware and software configuration information.

5.1

Auto Cal Feature

ACAL

Used to set up and operate the AutoCal feature.

5.2, 9.5

Only appears if the analyzer has one of the calibration valve

 

 

options installed.

 

Internal Data Acquisition

DAS

Used to set up the DAS system and view recorded data.

7

(DAS)

 

 

 

Analog Output Reporting

RNGE

Used to configure the output signals generated by the

5.4

Range Configuration

instruments analog outputs.

 

 

Calibration Password Security

PASS

Turns the calibration password feature ON/OFF.

5.5

Internal Clock Configuration

CLK

Used to set or adjust the instrument’s internal clock.

5.6

Secondary SETUP Mode

MORE

This button accesses the instruments secondary setup menu.

See

(Advanced SETUP features)

Table 4-5

 

 

 

 

 

 

4.3.3. SECONDARY SETUP MENU (SETUP MORE)

The areas accessed and configured under the secondary SETUP Mode menu are shown in Table 4-5.

Table 4-5: Secondary Setup Mode Features and Functions

 

CONTROL

 

 

MANUAL

MODE OR FEATURE

BUTTON

 

DESCRIPTION

SECTION

 

LABEL

 

 

 

External Communication

 

Used to set up and operate the analyzer’s various external I/O

 

COMM

channels including RS-232; RS-485, modem communication

8

Channel Configuration

 

and/or Ethernet access.

 

 

 

 

 

 

 

 

 

 

Used to view various variables related to the instruments

 

 

 

current operational status.

 

 

 

Changes made to any variable are not acknowledged and

 

System Status Variables

VARS

 

recorded in the instrument’s memory until the ENTR button

5.8

is pressed.

 

 

Pressing the EXIT button ignores the new setting.

 

 

 

If the EXIT button is pressed before the ENTR button, the

 

 

 

 

analyzer will beep alerting the user that the newly entered

 

 

 

 

value has been lost.

 

 

 

Used to access a variety of functions that are used to configure,

 

System Diagnostic Features

 

test or diagnose problems with a variety of the analyzer’s basic

 

and

DIAG

systems.

5.9, 5.9.2

Analog Output Configuration

 

Most notably, the menus used to configure the output signals

 

 

 

generated by the instruments’ analog outputs are located here.

 

Teledyne Analytical Instruments

93

Page 93
Image 93
Teledyne 9110T instruction manual Password Security, Primary Setup Menu, Secondary Setup Menu Setup MORE