Table 3-4. Diagnostic Test Details
Test | Description |
|
|
Remote User Video | Reports on whether a digital video channels are installed but |
| not working |
LAN Connection | Indicates whether LAN connection is active and whether |
| traffic has been seen since the last run of diagnostics. |
Indicates the total number of currently connected and | |
| powered SIP modules |
Offline SIP modules | Indicates the number of SIP modules that were connected |
| successfully in the past and are turned off |
Suspect SIP modules | Indicates the number of SIP modules that were detected, but |
| are either unavailable for connection or dropped packets |
| during the ping tests |
|
|
To run diagnostic tests:
1Press <Print Screen> to launch the OSCAR interface. The Main dialog box appears.
2Click Commands - Run Diagnostics. A warning message displays indicating that all users will be disconnected.
3Click OK to begin diagnostics. or
Click X or press <Escape> to exit the dialog box without running a diagnostic test.
4All users are disconnected and the Diagnostics dialog box displays.
5As each test is finished, a pass (green circle) or fail (red x) symbol displays. The test is complete when the last test’s symbol displays.
Broadcasting to Servers
The analog user can simultaneously control more than one server in a system to ensure that all selected servers receive identical input. You can choose to broadcast keystrokes and/or mouse movements independently.
NOTE: You can broadcast up to 16 devices at a time, one device per ARI port.
Controlling Your System at the Analog Ports
58