Fuser output sensor

1.Open the right door.

2.Lower the secondary transfer assembly.

3.Remove the fuser assembly, and then verify that the sensor flag on the fuser assembly moves freely. If the sensor flag does not move freely, replace the fuser. See Fuser on page 87.

Figure 3-7Test the fuser output sensor (1 of 2)

4.Insert a piece of paper to activate the sensor. Figure 3-8Test the fuser output sensor (2 of 2)

5.Check the control-panel display for a sensor response.

6.If there is no response, replace the fuser output sensor.

ENWW

Tools for troubleshooting 263

Page 299
Image 299
HP Enterprise 500 manual Fuser output sensor, Open the right door Lower the secondary transfer assembly