Table 1-9Converted DC voltages

Main DC voltage

Sub-voltage

Behavior

Notes

 

 

 

 

+24 V

+24VA

Stopped during Sleep

The 24V POWER SUPPLY

 

 

(powersave) mode

(24VRMT) signal controls

 

 

 

supply or interruption of

 

 

 

+24VA.

 

 

 

 

 

+24VB

Interrupted when the front

 

 

 

door or right door open

 

 

 

Stopped during Sleep

 

 

 

(powersave) mode

 

 

 

 

 

+5 V

+5VA

Supplied during Sleep

The VOLTAGE

 

 

(powersave) mode 2 and

CONVERSION (PWRSAVE)

 

 

Sleep (powersave) mode 3

signal converts output voltage

 

 

 

of +5VA into 3.2V.

 

 

 

 

 

+5VB

Supplied during Sleep

The 5V POWER SUPPLY

 

 

(powersave) mode 2

(VC5VOFF) signal sontrols

 

 

Stopped during Sleep

supply or interruption of

 

 

+5VB.

 

 

(powersave) mode 3

 

 

 

Supplies power to the

The VOLTAGE

 

 

CONVERSION (PWRSAVE)

 

 

formatter

signal converts output voltage

 

 

 

of +5VB into 3.2V

 

 

 

 

 

+5VC

Supplied during Sleep

the VOLTAGE CONVERSION

 

 

(powersave) mode 2 and

(PWRSAVE) signal converts

 

 

Sleep (powersave) mode 3

output voltage of +5VC into

 

 

Interrupted when the front

3.2V.

 

 

 

 

 

door or right door open

 

 

 

 

 

 

+5VD

Stopped during Sleep

 

 

 

(powersave) mode

 

 

 

Interrupted when the front

 

 

 

door or right door open

 

 

 

 

 

+3.3 V

3.3VA

Constantly supplied

 

 

 

 

 

 

3.3VB

Stopped only when the power

The 3V POWER SUPPLY

 

 

is off

(VC3VOFF) signal controls

 

 

Supplies power to the

supply or interruption of

 

 

+3.3VB.

 

 

formatter

 

 

 

 

 

 

3.3VC

Stopped during Sleep

 

 

 

(powersave) mode 2 and

 

 

 

Sleep (powersave) mode 3

 

 

 

 

 

ENWW

Engine control system 13