Table 3-2Heartbeat LED, product initialization (continued)

Product initializing

Heartbeat LED, normal state

Heartbeat LED, error state

state

 

 

 

 

 

 

 

 

HW checks on board

Green, solid

Red, solid

 

DRAM

 

Power on self check failure

 

 

 

 

 

Boot process halted

 

 

Replace the formatter.

 

 

 

Control panel

Green, solid

Yellow, fast flash

connection initializes

NOTE: Control panel communication

Formatter to control panel connection failed

 

 

successful. If an error occurs, a message should

 

Boot process continues

 

appear on the control-panel display.

 

 

 

Check the cables between the formatter and

 

 

control panel for damage. Make sure that the

 

 

cables are fully seated.

 

 

 

 

Preboot menu

Green, solid

Red, solid

 

available (including

 

Diagnostic failure

diagnostics)

 

 

 

 

Follow diagnostic instructions

 

 

Turn the power off, and then on again to restart

 

 

the initialization process.

 

 

 

Accessing disk for

Green, solid

Yellow, fast flash

firmware image

NOTE: If applicable, disk error messages

Control panel not connected

 

 

appear on the control-panel display.

 

 

 

 

 

 

Firmware boot

Green, solid

Yellow, fast flash

 

NOTE: If applicable, error messages appear

Control panel not connected

 

on the control-panel display.

 

 

 

 

 

 

Product operational

Green, heartbeat blink

Yellow, fast flash

 

NOTE: If applicable, error messages appear

Control panel not connected

 

on the control-panel display.

 

 

 

 

 

 

 

49.XX.YY error or

Not applicable

LED off

 

initialization freezes

NOTE: An error message (for example, 49.XX.YY) might appear on the control-panel display.

Eventually a formatter connection missing message will appear.

Turn the power off, and then on again to restart the initialization process.

If the error persists, perform a firmware upgrade.