Table 3-2Heartbeat LED, product initialization (continued)

Product initializing

Heartbeat LED, normal state

Heartbeat LED, error state

state

 

 

 

 

 

Control panel

Not applicable

Yellow, fast flash

connection interrupted

 

Control panel not connected

after the product is

 

operational

 

 

 

 

 

Sleep mode

Green, slow blink

Not applicable

 

 

 

Approaching Sleep

Green, slow blink

Not applicable

mode

 

 

 

 

 

Wake up from Sleep

Follows initialization progression above.

Follows initialization progression above.

mode

 

 

 

 

 

Approaching wake up

Follows initialization progression above.

Follows initialization progression above.

from Sleep mode

 

 

 

 

 

Connectivity LED, product operating

The following table describes the connectivity operation when the product completes the firmware boot process and is in the Ready state.

Table 3-3Heartbeat LED, product operational

LED color

Description

 

 

 

Green

Normal operation

 

 

Formatter is operating normally

 

 

Firmware is operating normally

 

 

Control panel is connected

 

 

 

Yellow

Formatter cannot connect to the control panel

 

 

Check control panel connections

 

 

Verify control panel functionality

 

 

 

 

ENWW

Tools for troubleshooting 249

Page 285
Image 285
HP Enterprise 500 manual Connectivity LED, product operating, 3Heartbeat LED, product operational