1 646
Download 646 pages 54.92 Kb
Page 523
Image 523

Table 3-39Causes and solutions for pickup stationary jams (continued)

Cause

Solution

 

 

The spring of the registration sensor lever is

Check the spring and place it in correct position.

unhooked.

 

 

 

Poor contact of the registration sensor

Reconnect the connector (J109) on the DC controller PCA.

connector.

 

 

 

The registration sensor is defective.

Run the sensor test to verify that the registration sensor is functioning properly.

 

If it is not, replace the registration assembly.

 

 

Jams in the duplex area (duplex models)

Table 3-40Causes and solutions for duplexing reverse jams

Cause

Solution

The duplex reverse roller is worn or deformed. Replace the delivery assembly.

The duplex feed roller is worn or deformed.

Replace the duplex feed unit.

 

 

Poor contact of the duplex reverse-motor

Reconnect the connectors (J202 and J201) on the high-voltage power supply

connector.

(upper) PCA and connector (J113) on the DC controller PCA.

 

 

The duplex reverse motor is defective.

Replace the duplex drive assembly.

 

 

Poor contact of the duplexing reverse-motor

Reconnect the connectors of the duplexing reverse motor (J20) and the

connector.

duplexing driver PCA (J202).

 

 

The duplexing reverse motor is defective.

Replace the right door assembly.

 

 

Table 3-41Causes and solutions for duplex repick jams

 

Cause

Solution

 

 

 

 

 

 

 

The duplexer re-feed sensor lever is set

Check the sensor lever to make sure it is set correctly. If it is damaged, replace

 

incorrectly or damaged.

the right door assembly.

 

 

 

 

 

 

 

 

The spring of the duplexer re-feed sensor lever

Check the spring and place it in correct position.

 

 

 

is unhooked.

 

 

 

 

 

 

 

 

 

Poor contact of the duplexer re-feed sensor

Reconnect the intermediate connector (J90) and connector (J107) on the DC

 

 

 

connector.

controller PCA.

 

 

 

 

 

 

 

 

The duplexer re-feed sensor is defective.

Run the sensor test to verify that the duplexer re-feed sensor is functioning

 

 

 

 

properly. If it is not, replace the right door assembly.

 

 

 

 

 

 

 

 

The spring of the duplexer-refeed-sensor lever

Check the spring and place it in the correct position.

 

 

 

is unhooked.

 

 

 

 

 

 

 

 

 

The duplexer-refeed-sensor lever is damaged.

Replace the duplexer re-feed sensor.

 

 

 

 

 

 

 

 

Poor contact of the duplexer-refeed-sensor

Reconnect the intermediate connector (J90) and connector (J107) on the DC

 

 

 

connector.

controller PCA. If the problem persist, replace duplexer re-feed sensor.

 

 

 

 

 

 

 

 

The duplexer re-feed sensor is defective.

Check the duplexer re-feed sensor. If the sensor is defective, replace the

 

 

 

 

duplexer re-feed sensor.

 

 

 

 

 

 

 