Fuser pressure-release sensor

1.Open the right door.

2.Lower the secondary transfer assembly.

3.Remove the fuser, and then rotate the gear (callout 1) to move the flag (callout 2). If the flag does not actuate, replace the fuser.

Figure 3-11Test the fuser pressure-release sensor (1 of 2)

2

1

4.Insert a piece of paper to activate the fuser pressure-release sensor. Figure 3-12Test the fuser pressure-release sensor (2 of 2)

5.Check the control-panel display for sensor response.

6.If there is no response, replace fuser pressure-release sensor.

266 Chapter 3 Solve problems

ENWW

Page 302
Image 302
HP Enterprise 500 manual Fuser pressure-release sensor