6.Close the right door and front door to verify that the switches close. Figure 3-17Test the right- and front-door interlock switches (3 of 4)

7.Open the right door and front door to verify that the switches open. Figure 3-18Test the right- and front-door interlock switches (4 of 4)

8.If the switches do not close, check the connectors on the DC controller PCA.

9.If the switches are opening/closing correctly when either door is open or closed, then check J118 on the DC controller.

10.If the connectors are securely connected to the DC controller PCA and the switches still do not close, replace the DC controller PCA.

270 Chapter 3 Solve problems

ENWW

Page 306
Image 306
HP Enterprise 500 manual Enww