59.05.08 or 59.05.09

1.Turn the product off, and then on.

2.Check the connector (J120) on the DC controller PCA.

3.Use the motor drive test in the componet test to verify that the motor is properly functioning. If it is not, replace the drum motor (M1).

59.05.10 or 59.05.11

1.Turn the product off, and then on.

2.Check the connector (J120) on the DC controller PCA.

3.Use the motor drive test in the componet test to verify that the motor is properly functioning. If it is not, replace the drum motor (M1).

59.05.12 or 59.05.13

1.Turn the product off, and then on.

2.Check the connector (J120) on the DC controller PCA.

3.Use the motor drive test in the componet test to verify that the motor is properly functioning. If it is not, replace the developing disengagement motor (M10).

4.Use the Manual sensor test to verify that the ITB alienation sensor (SR17) is properly functioning. If it is not, replace the ITB alienation sensor (SR17).

59.05.B0

1.Turn the product off, and then on.

2.Check the connector (J89) on the residual feed motor (M12), intermediate connectors (J75 and J77), and the connector (J137) on the DC controller.

3.Use the motor drive test in the componet test to verify that the motor is properly functioning. If it is not, replace the developing disengagement motor (M12).

4.Use the Manual sensor test to verify that the ITB alienation sensor (SR17) is properly functioning. If it is not, replace the ITB alienation sensor (SR17).

60.00.0Y Tray <Y> lifting error

Description

Tray lift motors error

Recommended action

60.00.11