LaserSpeed 8000-3 Instruction Handbook
N | Analog Zero Scale Velocity |
N<CR> Read
Response Format: <N>
N<N><CR> Set
<N> is the velocity value * 1000 corresponding to the zero scale output of the
Note: Changing this setting will cause a reset, will reset the indicated length, and will cause the pulse outputs to be momentarily interrupted. Do not change this setting during normal operation.
E | Filter Range Enables |
E<CR> Read
Response Format: <N>
E<N><CR> Set
<N> is an integer that should normally be set to 31.
This setting should normally be left at 31 and should not be modified. The LS8000 will not work properly if this setting is set incorrectly. LaserTrak uses this value to configure the minimum and maximum measurable speeds. Only change this setting if specifically instructed to do so by a Beta LaserMike Service Engineer.
S | Material Present Input Mode |
S<CR> Read
Response Format: <N>
S<N><CR> Set
<N> is an integer from 0 to 2 indicating the Material Present Input Mode.
Value | Description | |
0 | Use Internal Material Present | |
|
| |
| External Material Present (Active Low) | |
1 | MP High | Low transition starts a measurement |
| MP Low | High transition ends measurement |
|
| |
| External Material Present (Active High) | |
2 | MP Low | High transition starts a measurement |
| MP High | Low transition ends measurement |
|
|
|
Note: To disable the Material Present feature and have Material Present on all the time, set the Material Present Input Mode to External Active Low and leave the Material Present input disconnected.
Part No. 93463 / Drawing No. | Page 132 of 221 | Revision A (Sep 2007) |