| LaserSpeed | |
|
|
|
| Installing the System | |
|
|
|
|
| |
| DB37 |
| Description | ||
| 1 | 1 | 1 | RS232 Transmit (from | |
|
|
|
|
| |
| 2 | 2 | 2 | RS232 Receive (from host to | |
|
|
|
|
| |
| 3 | 3 | 3 | Phase A True – High Speed Output | |
|
|
|
|
| |
| 4 | 4 | 4 | Phase A False – User Scaleable | |
|
|
|
|
| |
| 5 | 5 | 5 | Phase A False – High Speed Output | |
|
|
|
|
| |
| 6 | 6 | 6 | Phase B True – User Scaleable | |
|
|
|
|
| |
| 7 | 7 | 7 | Phase B True – High Speed Output | |
|
|
|
|
| |
| 8 | 8 | 8 | Phase B False – User Scaleable | |
|
|
|
|
| |
| 9 | 9 | 9 | Phase B False – High Speed Output | |
|
|
|
|
| |
| 10 | 10 | 10 | Material Present Input | |
|
|
|
|
| |
| 11 | 11 | 11 | Signal Ground for Inputs/Outputs/Serial | |
|
|
|
|
| |
| 12 | 12 | 12 | Power Ground for 24V Input | |
|
|
|
|
| |
| 13 | 13 | 13 | Power Ground for 24V Input | |
DB25 | 14 | 14 | 14 | Measurement Direction Input | |
|
|
|
|
| |
| 15 | 15 | 15 | Phase A True – User Scaleable | |
|
|
|
|
| |
| 16 | 16 | 16 | Laser Interlock (Connect to Signal Ground to Turn On Laser) | |
|
|
|
|
| |
| 17 | 17 | 17 | Shutter Control (Connect to Signal Ground to Open Shutter) | |
|
|
|
|
| |
| 18 | 18 | 18 | Length Reset Input | |
|
|
|
|
| |
| 19 | 19 | 19 | Signal Ground for Inputs/Outputs/Serial | |
|
|
|
|
| |
|
|
|
| User VIN – Voltage input for Isolated Pulse Outputs (5 to 28V | |
| 20 | 20 | 20 | DC). The voltage supplied will be the voltage level of the pulse | |
| outputs supplied by the | ||||
|
|
|
| ||
|
|
|
| the pulse outputs will be approximately 4.5V. | |
|
|
|
|
| |
| 21 | 21 | 22 | Signal Ground for Inputs/Outputs/Serial | |
|
|
|
|
| |
| 22 | 22 | 24 | Index Pulse True - User Scaleable | |
|
|
|
|
| |
| 23 | 23 | 25 | Index Pulse False - User Scaleable | |
| 24 | 24 | 26 | 24V Fused Input | |
|
|
|
|
| |
| 25 | 25 | 27 | 24V Fused Input | |
|
|
|
|
| |
| 1 | 26 | 28 | RS422 Transmit + (from | |
|
|
|
|
| |
| 2 | 27 | 29 | RS422 Transmit – (from | |
|
|
|
|
| |
| 3 | 28 | 30 | RS422 Receive + (from host to | |
|
|
|
|
| |
DB9 | 4 | 29 | 31 | RS422 Receive – (from host to | |
|
|
|
| ||
6 | 30 | 32 | Analog Output Voltage | ||
| |||||
|
|
|
|
| |
| 7 | 31 | 33 | Analog Output Ground | |
|
|
|
|
| |
| 8 | 32 | 34 | Measurement Synchronization Input + | |
|
|
|
|
| |
| 9 | 33 | 35 | Measurement Synchronization Input - | |
|
|
|
|
| |
| 1 | 34 | 36 | Ethernet TX+ | |
|
|
|
|
| |
M12 | 2 | 35 | 37 | Ethernet RX+ | |
|
|
|
| ||
3 | 36 | 38 | Ethernet TX- | ||
| |||||
|
|
|
|
| |
| 4 | 37 | 39 | Ethernet RX- | |
|
|
|
|
|
Part No. 93463 / Drawing No. | Page 29 of 221 | Revision A (Sep 2007) |