Laser LS8000-3 Application Interfaces, Light Stack Interface, Setting Value Command, #9CR, $L9CR

Models: LS8000-3

1 221
Download 221 pages 9.92 Kb
Page 71
Image 71

LaserSpeed 8000-3 Instruction Handbook

Interfacing with the LS8000-3

Application Interfaces

Light Stack Interface

The LS8000-3 User Scaleable Pulse Outputs and Index Pulse output can be reconfigured and connected to a light stack in order to indicate the current state of the laser in order to warn people in the area of laser radiation. The pulse outputs can be reconfigured into a light stack interface by setting the following settings:

Setting

Value

Command

Index Pulse Output Function

Light Stack (Green)

#9<CR>

User Scaleable Pulse Output

Light Stack (Yellow/Red)

$L9<CR>

Configuration

 

 

The outputs can then be connected to solid state relays in order to drive a light stack as shown below. This will provide a contact closure for each lamp. The maximum current that can be driven by this interface will depend on the selected relay.

Part No. 93463 / Drawing No. 0921-01561