LaserSpeed 8000-3 Instruction Handbook

Interfacing with the LS8000-3

 

Material Present

 

Material Present

Transition Effect

 

Input Mode

 

High (5-24V)

Low (0V)

Low High

High Low

 

 

 

 

 

 

 

 

 

 

 

0 (Internal)

N/A

N/A

No Effect

No Effect

 

 

 

 

 

 

1

 

No

Yes

Ends Current

Starts New

 

(External Active

("Material Not

("Material Is

 

Measurement

Measurement

 

Low)

Present")

Present")

 

 

 

 

 

 

 

 

 

2

 

Yes

No

Starts New

Ends Current

 

(External Active

("Material Is

("Material Not

 

Measurement

Measurement

 

High)

Present")

Present")

 

 

 

 

 

 

 

 

 

 

Note: If Material Present functionality isn't required, and you want Material Present to always be on, then set the LS8000-3's Material Present Input Mode to External Active Low, and leave the Material Present Input disconnected.

Part No. 93463 / Drawing No. 0921-01561

Page 44 of 221

Revision A (Sep 2007)

Page 44
Image 44
Laser LS8000-3 manual Material Present Transition Effect Input Mode