LaserSpeed 8000-3 Instruction Handbook
Siemens Counter Module 6ES5 385-8MB11
Quadrature Pinout
Signal | Siemens | LaserSpeed |
Signal A | 7 | 15 |
|
|
|
Signal | 6 | 4 |
|
|
|
Signal B | 9 | 6 |
|
|
|
Signal | 10 | 8 |
|
|
|
Signal Ground | 3 | 11 |
|
|
|
User Voltage | 1 | 20 |
|
|
|
Pulsed Pinout
Signal | Siemens | LaserSpeed |
Signal A | 7 | 15 |
|
|
|
Signal | 6 | 4 |
|
|
|
Signal Ground | 3 | 11 |
|
|
|
User Voltage | 1 | 20 |
|
|
|
Notes:
Configure the LaserSpeed pulse per unit length Set scaling in the Siemens counter
Set count mode in the Siemens counter (single, quad, quad x2…)
Part No. 93463 / Drawing No. | Page 93 of 221 | Revision A (Sep 2007) |