LaserSpeed 8000-3 Instruction Handbook

RS-232/RS-422 Communication

*GINFO

Gauge Model and Serial Number

*GINFO?<CR> Read Only Command

Response Format: *GINFO=<LS8000-3XXX#XXXX-XXX-XXXX><CR>

This read-only command can be used to read back the LS8000-3 model number and serial number. The text before the # character indicates the Model Number, and the text after the

#character indicates the Serial Number. Example:

Command: *GINFO?

Response: *GINFO=LS8000-310X#1234-567-890

This response indicates a model number of "LS8000-310X", and a serial number of "1234- 567-890"

*ETHERNET

 

 

Ethernet Enabled

*ETHERNET?<CR>

Read Only Command

 

Response Format: *ETHERNET=<N><CR>

This is a read-only command that returns 1 if the Ethernet option is installed, and 0 if the Ethernet option is not installed.

If the Ethernet option is not installed, then all Ethernet settings can be disregarded.

*MACID

 

 

Ethernet Hardware ID

*MACID?<CR>

Read Only Command

 

Response Format: *MACID=<XX:XX:XX:XX:XX:XX><CR>

This read-only command returns the Ethernet hardware ID. Each LS8000-3 is assigned a unique identifier, even if the Ethernet option is not installed.

This setting can be disregarded if the Ethernet option is not installed.