LaserSpeed 8000-3 Instruction Handbook

RS-232/RS-422 Communication

*LOCKED

Setting Lock

*LOCKED?<CR> Read

Response Format: *LOCKED=<N><CR>

*LOCKED=<N><CR> Set

<N> is either 0 or 1. This setting controls the Settings Lock. In order to prevent accidental changes to the LS8000-3's configuration settings, you must explicitly unlock the settings before any changes can be made.

Unlock Command: *LOCKED=0<CR>

Relock Command: *LOCKED=1<CR>

After unlocking the settings with *LOCKED=0<CR>, you can change settings. If you try to change setting without unlocking the LS8000-3, the changes will be ignored.

The LS8000-3 will automatically re-arm the Setting Lock after 1 minute.

*LOCKEN

Setting Lock Enabled

*LOCKEN?<CR> Read

Response Format: *LOCKEN=<N><CR>

*LOCKEN=<N><CR> Set

<N> is either 0 or 1. If you are manually changing many settings over a period of time, the Settings Lock can a become nuisance, so you may wish to disable it. Before the Settings Lock can be disabled, however, the settings must be unlocked:

To disable Settings Lock:

*LOCKED=0<CR>

*LOCKEN=0<CR>

To re-enable Settings Lock:

*LOCKEN=1<CR>

The Settings Lock should be re-enabled after configuration is completed, and the LS8000-3 is to be placed into normal operation.