Laser LS8000-3 Text Output Mode, Format Description Examples, Bit Status Field Convention

Models: LS8000-3

1 221
Download 221 pages 9.92 Kb
Page 155
Image 155

LaserSpeed 8000-3 Instruction Handbook

RS-232/RS-422 Communication

TE

Text Output Mode

TE<CR> Data Output Command

Data Format: <L,V,QF,ST><CR>

This command places the LS8000-3 into Text Output Mode. This mode only affects the communication port over which the command is sent. For example, if the command is sent over RS-232, only the RS-232 port will transmit measurement data—the RS-422 and Ethernet ports will not change operation.

The LS8000-3 will output a serial message at an interval determined by the User Update Rate (O setting). This rate can vary from 1ms to 2.047s. If using a fast update rate, it may not be possible to transmit every reading at lower baud rates. Refer to the Real-Time Data Timing Considerations section for details.

The measurement data is a comma delimited list of the current measurement data outputs. The response string is always 28 characters. All fields are zero-padded to form a constant length string.

Format:

 

 

 

 

 

±LLLLLLLLL,±VVVVVVVVV,QF,ST<CR>

 

 

1234567890123456789012345678

 

 

 

1

2

 

 

 

 

 

 

 

 

 

Value

Format

 

Description

Examples

 

L

Integer x 1000

 

Current Length

+000001209

(+1.209)

 

(Signed)

 

 

-000000342 (-0.342)

V

Integer x 1000

 

Current Velocity

+000120321

(+120.321)

 

(Signed)

 

 

-000034131 (-34.131)

QF

Integer

 

Quality Factor

15

 

 

 

 

04

 

 

 

 

 

 

 

 

 

 

 

 

ST

Integer

 

Status

63

 

 

 

 

47

 

 

 

 

 

 

 

 

 

 

 

 

The Status value is a bit field that has the following format:

Bit

Status Field

Convention

0

Laser @ Temperature

Yes=1 / No=0

 

 

 

1

Laser Interlock Open/Closed

Closed=1 / Open=0

 

 

 

2

Shutter Open/Closed

Open=1 / Closed = 0

 

 

 

3

Material Present

Yes=1 / No=0

 

 

 

4

Valid Measurement

Yes=1 / No=0

 

 

 

5

System Ready (Indicates Interlock

Yes=1 / No=0

 

Closed, Shutter Open, and Laser @

 

 

Temperature)

 

 

 

 

Part No. 93463 / Drawing No. 0921-01561

Page 155 of 221

Revision A (Sep 2007)

Page 155
Image 155