LaserSpeed 8000-3 Instruction Handbook

LaserTrak Software

Lower Tolerance: allows the user to alarm on measurements below this threshold

Upper Tolerance: allows the user to alarm on measurements above this threshold

#of Samples: indicates how many samples are used in the calculations Velocity displays the speed of the parts being measured

Mean: shows the mean statistic of all lengths included in the measurement

Std Dev: is the standard deviation of all parts included in the measurement Min Length Read displays the shortest length measured

%Dev from Mean: displays the percent of deviation of the shortest length from the mean

Max Length Read: displays the longest length measured

%Dev from Mean: displays the percent of deviation of the longest length from the mean

Part No. 93463 / Drawing No. 0921-01561

Page 120 of 221

Revision A (Sep 2007)

Page 120
Image 120
Laser LS8000-3 manual Part No / Drawing No 120 Revision a Sep