Laser LS8000-3 manual User Scaleable Pulse Rate, Pncr

Models: LS8000-3

1 221
Download 221 pages 9.92 Kb
Page 147
Image 147

 

 

 

LaserSpeed 8000-3 Instruction Handbook

 

 

 

RS-232/RS-422 Communication

 

 

 

User Scaleable Pulse Rate

P

 

 

P<CR>

Read

 

Response Format: <N>

P<N><CR>

Set

 

<N> is an integer from 0 to 999,999,999 that is the number of pulses per unit length scaled

 

by 1000.

 

The User Scaleable Pulse Output can output pulses at rates higher than 250kHz. Caution

 

should be used to ensure that the maximum line speed encountered during operation does

 

not cause the pulse output frequency to exceed the maximum frequency of the counter.

 

Many counters have surprisingly low maximum frequency specifications. If the pulse

 

frequency exceeds the counter maximum frequency, the counter may behave erratically.

 

Example:

 

Want 100 pulses/inch

 

Measurement Units are inches/minute

 

Pulses/Length = 100 x 1000 = 100000

 

Command to set the value is: P100000<CR>

 

Note: Changing this setting will cause a reset, will reset the indicated length, and will cause

 

the pulse outputs to be momentarily interrupted. Do not change this setting during normal

 

operation.

 

 

 

Read Firmware Version

Z

 

 

Z<CR>

Read Only Command

 

Response Format: LS8KV*<CR>

 

Where * is a capital letter indicating the firmware version.

Part No. 93463 / Drawing No. 0921-01561

Page 147 of 221

Revision A (Sep 2007)