LaserSpeed 8000-3 Instruction Handbook
TT | Configurable Text Output Mode |
TT<CR> Data Output Command
Response Format: Variable
TT<N><CR> Set
<N> specifies the output format. The value can be set with a command such as TT15<CR> (sets the format to 15). To start receiving data, send the command TT<CR>. This output mode allows you to turn on and off parts of the serial output message, which can make the data simpler to process and reduce the number of bytes being transmitted.
Value Format
6<TT,V,Q><CR>
15<TT,L,V,Q,S><CR>
13<TT,L,Q,S><CR>
14<TT,V,Q,S><CR>
77<TT,L,Q,S,T><CR>
78<TT,V,Q,S,T><CR>
79<TT,L,V,Q,S,T><CR>
Where:
Notation | Description | Length (Bytes) |
TT | Current Value of TT Setting | Varies |
L | Length * 1000 | 10 |
|
|
|
V | Velocity * 1000 | 10 |
|
|
|
Q | Quality Factor | 2 |
|
|
|
S | Status | 2 |
|
|
|
T | Temperature * 100 | 4 |
|
|
|
Example:
To set TT to 79, and then start receiving data:
1)Send TT79<CR>
2)Send TT<CR>
The
79,+000000370,000012348,15,63,3125<CR>
79,+000000494,000012347,15,63,3125<CR>
79,+000000617,000012345,15,63,3125<CR>
Part No. 93463 / Drawing No. | Page 158 of 221 | Revision A (Sep 2007) |