Laser LS8000-3 Configurable Text Output Mode, Ttncr Set, Value Format, Send TT79CR Send Ttcr

Models: LS8000-3

1 221
Download 221 pages 9.92 Kb
Page 158
Image 158

LaserSpeed 8000-3 Instruction Handbook

RS-232/RS-422 Communication

TT

Configurable Text Output Mode

TT<CR> Data Output Command

Response Format: Variable

TT<N><CR> Set

<N> specifies the output format. The value can be set with a command such as TT15<CR> (sets the format to 15). To start receiving data, send the command TT<CR>. This output mode allows you to turn on and off parts of the serial output message, which can make the data simpler to process and reduce the number of bytes being transmitted.

Value Format

6<TT,V,Q><CR>

15<TT,L,V,Q,S><CR>

13<TT,L,Q,S><CR>

14<TT,V,Q,S><CR>

77<TT,L,Q,S,T><CR>

78<TT,V,Q,S,T><CR>

79<TT,L,V,Q,S,T><CR>

Where:

Notation

Description

Length (Bytes)

TT

Current Value of TT Setting

Varies

L

Length * 1000

10

 

 

 

V

Velocity * 1000

10

 

 

 

Q

Quality Factor

2

 

 

 

S

Status

2

 

 

 

T

Temperature * 100

4

 

 

 

Example:

To set TT to 79, and then start receiving data:

1)Send TT79<CR>

2)Send TT<CR>

The LS8000-3 will start transmitting data in this format:

79,+000000370,000012348,15,63,3125<CR>

79,+000000494,000012347,15,63,3125<CR>

79,+000000617,000012345,15,63,3125<CR>

Part No. 93463 / Drawing No. 0921-01561

Page 158 of 221

Revision A (Sep 2007)

Page 158
Image 158
Laser LS8000-3 manual Configurable Text Output Mode, Ttncr Set, Value Format, Notation Description Length Bytes