LaserSpeed 8000-3 Instruction Handbook
Interfacing with the
Domino A Series
Pinout
Signal | Domino A200 | LaserSpeed |
Signal A | 2 | 15 |
|
|
|
Print Go | 3 | 22 |
|
|
|
Signal Ground | 1 | 11 |
|
|
|
User Voltage | 4 | 20 |
|
|
|
Notes:
Configure the LaserSpeed for the appropriate pulse per unit length. The index pulse should be set to trigger at the appropriate rate (every 2 feet, every 1 meter, etc), and with a 20 ms pulse width.
On the Domino
There are two ports that are in parallel so it doesn’t matter which one is used. The other port would not be used. The printer should be set for EXTERNAL print and the REPEAT PRINTING should be turned off.
Part No. 93463 / Drawing No. | Page 84 of 221 | Revision A (Sep 2007) |