LaserSpeed 8000-3 Instruction Handbook

RS-232/RS-422 Communication

Note: Some of the above outputs were previously described under the Index Pulse Output Function setting.

Light Stack (Yellow)

This output can be used to drive a solid-state relay to turn on the yellow light in a light stack. The yellow light is illuminated when the LS8000-3 laser is turned on, but the beam shutter is closed, indicating that the LS8000-3 is not emitting laser radiation. See the Light Stack Interface section for details.

Voltage High: Yellow lamp should be illuminated

Voltage Low: Yellow lamp should not be illuminated

Light Stack (Red)

This output can be used to drive a solid-state relay to turn on the red light in a light stack. The red light is illuminated when the LS8000-3 laser is turned on, and the beam shutter is open, indicating that the LS8000-3 is emitting laser radiation. See the Light Stack Interface section for details.

Voltage High: Yellow lamp should be illuminated

Voltage Low: Yellow lamp should not be illuminated

Length Threshold A

Indicates when the current length has exceeded the Length Threshold A set point. This output is reset when the Index Pulse resets. See the Index Pulse/Length Thresholds section for details about length thresholds.

Voltage High: Length Threshold A Exceeded

Voltage Low: Length Threshold A Not Exceeded

Length Threshold B

Indicates when the current length has exceeded the Length Threshold B set point. This output is reset when the Index Pulse resets. See the Index Pulse/Length Thresholds section for details about length thresholds.

Voltage High: Length Threshold A Exceeded

Voltage Low: Length Threshold A Not Exceeded

Part No. 93463 / Drawing No. 0921-01561