LaserSpeed 8000-3 Instruction Handbook
Note: Some of the above outputs were previously described under the Index Pulse Output Function setting.
Light Stack (Yellow)
This output can be used to drive a
Voltage High: Yellow lamp should be illuminated
Voltage Low: Yellow lamp should not be illuminated
Light Stack (Red)
This output can be used to drive a
Voltage High: Yellow lamp should be illuminated
Voltage Low: Yellow lamp should not be illuminated
Length Threshold A
Indicates when the current length has exceeded the Length Threshold A set point. This output is reset when the Index Pulse resets. See the Index Pulse/Length Thresholds section for details about length thresholds.
Voltage High: Length Threshold A Exceeded
Voltage Low: Length Threshold A Not Exceeded
Length Threshold B
Indicates when the current length has exceeded the Length Threshold B set point. This output is reset when the Index Pulse resets. See the Index Pulse/Length Thresholds section for details about length thresholds.
Voltage High: Length Threshold A Exceeded
Voltage Low: Length Threshold A Not Exceeded
Part No. 93463 / Drawing No. | Page 146 of 221 | Revision A (Sep 2007) |