Configuring Interface’s PIM-DM Configuration Page
Selection Criteria
Slot/Port - Select the Slot and port for which data is to be displayed or configured. Slot 0 is the base unit. You must have configured at least one router interface before configuring or displaying data for a
Configurable Data
Interface Mode - Select enable or disable from the pulldown menu to set the administrative status of
Hello Interval - Enter the number of seconds between PIM hello messages transmitted from the selected interface. The default value is 30. Valid values are from (10 to 3600).
Command Buttons
Submit - Send the updated configuration to the router. Configuration changes take effect immediately. These changes will not be retained across a power cycle unless a save is performed.
Viewing Interface’s PIM-DM Configuration Page
Selection Criteria
Slot/Port - Select the physical interface for which data is to be displayed. There must be configured at least one router interface before displaying data for a
Non-Configurable Data
Interface Mode - Displays the administrative status of
634