Fortinet MR1 manual Ip igmp robustness, Ip igmp startup-query-count

Models: MR1

1 640
Download 640 pages 32.63 Kb
Page 392
Image 392

no - This command resets the maximum response time interval for the specified interface, which is the maximum query response time advertised in IGMPv2 queries on this interface to the default value. The maximum response time interval is reset to the default time.

Default Setting

100

Command Mode

Interface Config

7.2.2.7ip igmp robustness

This command configures the robustness that allows tuning of the interface. The robustness is the tuning for the expected packet loss on a subnet. If a subnet is expected to have a lot of loss, the Robustness variable may be increased for the interface.

Syntax

ip igmp robustness <1-255> no ip igmp robustness

<1-255> - The range for <1-255>is 1 to 255.

no - This command sets the robustness value to default.

Default Setting

2

Command Mode

Interface Config

7.2.2.8ip igmp startup-query-count

This command sets the number of Queries sent out on startup, separated by the Startup Query Interval on the interface.

Syntax

ip igmp startup-query-count <1-20> no ip igmp startup-query-count

<1-20> - The range for <1-20>is 1 to 20.

392

Page 392
Image 392
Fortinet MR1 manual Ip igmp startup-query-count, Syntax Ip igmp robustness 1-255 no ip igmp robustness