measures the absolute power amplitude at input B.

calculates and displays the complex ratio of input B to input R.

deletes the last character entered.

sets the background intensity of the LCD as a percent of white. The factory-set default value is stored in non-volatile memory.

(Option 010 only) sets the time-domain bandpass mode.

toggles an annunciator which sounds to indicate completion of certain operations such as calibration or instrument state save.

turns the limit fail beeper on or off. When limit testing is on and the fail beeper is on, a beep is sounded each time a limit test is performed and a failure detected. The limit fail beeper is independent of the warning beeper and the operation complete beeper.

toggles the warning annunciator. When the annunciator is on it sounds a warning when a cautionary message is displayed.

switches off the analyzer’s display. This feature may be helpful in prolonging the life of the LCD in applications where the analyzer is left unattended (such as in an automated test system). Pressing any front panel key will restore the default display operation.

adjusts the brightness of the color being modified. See Adjusting Color for an explanation of using this softkey for color modification of display attributes.

is used to enter the CO term in the definition of an OPEN standard in a calibration kit, which is the constant term of the cubic polynomial and is scaled by 10-15.

is used to enter the Cl term, expressed in F/Hz (Farads/Hz) and scaled by 10Sz7.

is used to enter the C2 term, expressed in F/Hz2 and scaled by 10-36.

is used to enter the C3 term, expressed in F/I-h8 and scaled by 10-45.

key leads to a series of menus to perform measurement

calibrations for vector error correction (accuracy enhancement), i....... c.;.......................... i

ad for specifying the calibration s-d=& used. me ~~~

key also leads to softkeys which activate interpolated error correction and power meter calibration.

accepts a power sensor calibration factor % for the segment.

brings up the segment modify menu and segment edit (calibration factor menu) which allows you to enter a power sensor’s calibration factors. The calibration factor data entered in this menu will be stored for power sensor A.

sets the preset state of interpolated error-correction on or off.

8-6 Key Definitions