jumps to one of the six sequence positions (SEQUENCE 1 through 6) if the limit test fails. This command executes any sequence residing in the selected position. Sequences may jump to themselves as well as to any of the other sequences in memory. When this softkey is pressed, the analyzer presents a softkey menu showing the six sequence positions and the titles of the sequences located in them. Choose the destination sequence to be called if the limit test fails.

jumps to one of the six sequence positions (SEQUENCE 1 through 6) if the limit test passes This command executes any sequence residing in the selected position. Sequences may jump to themselves as well as to any of the other sequences in memory. When this softkey is pressed, the analyzer presents a softkey menu showing the six sequence positions, and the titles of the sequences located in them. Choose the sequence to be called if the limit test passes (destination sequence).

prompts the user to select a destination sequence position (SEQUENCE 1 through 6). When the value of the loop counter reaches zero, the sequence in the specified position will run.

prompts the user to select a destination sequence position (SEQUENCE 1 through 6). When the value of the loop counter is no longer zero, the sequence in the specified position will nm.

displays only the imaginary (reactive) portion of the measured data on a Cartesian format. This format is similar to the real format except that reactance data is displayed on the trace instead of impedance data.

increments the value of the loop counter by 1.

initiahzes the disk unit number and volume number selected in the HP-IB menu, then returns to the disk menu. If more than one hard disk volume is to be initialized, each volume must be selected and initialized individually.

leads to the initialize menu. Before data can be stored on a disk, the disk must be initialized. If you attempt to store without initializing the disk, the message “CAUTION: DISK MEDIUM NOT INITIALIZED” is displayed. The disk format can be selected to be either logical interchange format (LIP), or DOS.

accesses a menu that allows you to measure the R, A, and B channels.

presents the instrument mode menu. This provides access to the primary modes of operation (analyzer modes).

sets the LCD intensity as a percent of the brightest setting. The factory-set default value is stored in non-volatile memory.

leads to a series of service tests

selects the analyzer internal disk for the storage device.

selects internal non-volatile memory as the storage medium for subsequent save and recall activity.

Key Definitions 9-l 9

Page 508
Image 508
HP 8753E manual Key Definitions 9-l