Example

The following example configures port NETP5 capabilities to 100half, 100full and flowcontrol.

Console(config)#interface ethernet NETP5

Console(config-if)#no capabilities 10half

Console(config-if)#no capabilities 10hfull

Console(config-if)#no capabilities 1000full

Console(config-if)#capabilities 100half

Console(config-if)#capabilities 100full

Console(config-if)#capabilities flowcontrol

Console(config-if)#

Related Commands

negotiation (4-86)

speed-duplex(4-85)

flowcontrol (4-89)

4.3.8.6flowcontrol

Use this command to enable flow control. Use the no form to disable flow control.

Note – The integrated switches in the Sun Fire B1600 blade system chassis are each composed of two switch chips linked together. It is only possible to enable flow control between two ports on the same switch chip. The ports NETP0, NETP1, NETP4, NETP5, and SNP8 through SNP15 are on one switch chip. The ports NETP2, NETP3, NETP6, NETP7, and SNP0 through SNP7 are on the other. (If you look at the rear panel of the SSC, all the ports on the right are on one chip, and all the ports on the left are on the other.)

Syntax

flowcontrol

no flowcontrol

Default Setting

Flow control enabled

Chapter 4 Command-Line Reference 4-89

Page 287
Image 287
Sunfire B1600 manual Flowcontrol