![](/images/new-backgrounds/1194842/194842337x1.webp)
2.Install the new separation corona unit.
a.Align the 2 locking tabs on the separation corona unit [1] with the keyholes cut out of the plate [3]. (It helps to hold the top cover down slightly for better access to the separation corona unit.)
b. Push the separation corona unit against the plate so that the tabs are inserted into the keyholes, as illustrated above.
c. Being careful not to touch the separation corona wire, use the handle
[2] to slide the separation corona unit to the front of the printer. Each tab locks into the narrow end of its keyhole.
d.Make sure that the separation corona unit is firmly attached to the plate. If it is not, repeat step 2a through step 2c.
e.Close the top cover and front door.