Cleaning the Separation Corona Wire

When you replace a photoconductor drum cartridge, you should also clean the separation corona wire. Use the following procedure to clean the separation corona wire.

1.Open the top cover to see the separation corona unit and the wire cleaner.

2.Remove the wire cleaner from inside the printer. The separation corona wire is very thin and delicate, so be careful not to break it.

3. Put the padded end of the wire cleaner on the separation corona unit.

Chapter 5. Replacing Supplies 5–39

Page 113
Image 113
IBM S544-5361-01 quick start Cleaning the Separation Corona Wire