Powering Up

You can power up the V-Switch 3000 once you have connected and powered up the storage devices. The V-Switch 3000 contains a storage auto-discovery function. At power- up the V-Switch 3000 automatically scans for and registers all attached and powered up network storage devices. Therefore, power up all storage devices before powering up the V- Switch 3000. Storage devices added after V-Switch 3000 power- up will be registered in the next V-Switch 3000 storage network scan.

The V-Switch 3000 contains two removable auto-switch 100V/230V AC redundant power supplies.

10242

Redundant

Power Supplies

Figure 24. V-Switch 3000 Power Supplies

Reconfirm that all storage devices are powered up and connected to the V- Switch. Plug the power cables into the V-Switch 3000 power supplies and then into the power source. Push the power switch to the ON position. The V-Switch 3000 powers up.

The Power indicator LED on the front right of the V-Switch 3000 turns green.

Each network port 1 Gb indicator LED turns green only if connected to the network and operating at 1 Gb.

Each storage port indicator LED on the front right of the V-Switch 3000 is green if connected to storage.

The fans start operating.

The LCD panel displays “V-Switch 3000 SANRAD Corp.”

You are now able to initialize the V-Switch 3000.